部屋データとアイテムデータのすべてのロジカル(Yes/No)フィールドと数値(数字)フィールドをチェックするルールを作成することができます。
ルールを設定するフィールドを選択すると、自動的にタイプが決定されます。表1は、フィールドのタイプと作成可能なルールのタイプとの相関関係を示しています。
Room Data field: | Item Data field: | Can be counted down: | Result: |
Logical | Logical | No | Under-specified If the Item field is "Yes", the field must also be "Yes". Example: If the Item is flagged for vacuum, the field "vacuum" must also be flagged. Over-specified: If there are no Item in the room with the "Yes" field, neither shall the field have "Yes". Example: If no Item in the room require vacuum, the field "vacuum" shall not be flagged. |
Numerical | Logical | Yes | Under-specified The field must be equal to or greater than the number of Item in the room where the Item field is flagged. Example: If the Item is flagged for power supply, the number of sockets in the room must be greater than or equal to the total of all these Item which require power supply. Over-specified: The field must not be greater than the number of Item in the room where the Item field is flagged. Example: The number of power sockets in the room must not be greater than the number of Item which require power. |
Logical | Numerical | No | Under-specified If an Item in the room has a field greater than 0, the field must be flagged. Over-specified: If no Item in the room has a field greater than 0, the field must not be flagged. |
Numerical | Numerical | No | Under-specified You can choose an operator with which to compare values. If you choose '>', the value of the Item field must be greater than or equal to the value in the field. If you choose the '<' operator, the Item field must be less than or equal to the field. Example: The minimum temperature for the Item must be greater than or equal to the minimum temperature in the room. Over-specified: Reverse the operator selected (for under-specified). For example: The minimum temperature for the Item must not be less than the minimum temperature in the room. Check whether over-specified for this type of rule actually has any practical significance. |
Numerical | Numerical | Yes | Under-specified (仕様不足): The sum of the Item field for all Items in the room must be less than or equal to the value in the field. Example: The number of data connections for all Item in the room must be less than or equal to the number of data outlets in the room. Over-specified (過剰仕様): The value in the field must not be greater than the total of the Item field for all Items in the room. For example: The number of data connections for all Items in the room must not be greater than the number of data outlets in the room. |
表1
ホーム → 部屋 → 部屋データ<-> アイテムチェックでルールの作成と削除ができます。これにより、定義されたすべてのルールの概要が表示されます。”追加 (Add)”をクリックしてルールを追加します。画面の左側にはすべてのフィールドが表示されたツリーがあり、右側にはすべてのアイテムフィールドが表示されたツリーがあります。これらのフィールドの中から、必要なフィールドをダブルクリックして1つずつ選択します。選択したフィールドのタイプによって、リソースをカウントダウンするかどうかと、使用する演算子のオプションがあります。ルールの設定が完了すると、アンダー・スペック (仕様不足)とオーバー・スペック (過剰仕様)それぞれのテキスト・フィールドにその定義が表示されます。次に優先度を選択し、OKをクリックします。